Enterotube bd becton pdf

Catalog number 212116 enterotube interpretation guide need 1 becton, dickinson, and company. Bcell biology and phenotypes using bd biosciences flow cytometry products, including instruments, reagents, and protocols. Bd, bd logo and all other trademarks are the property of becton, dickinson. Bd phoenix automated identification and susceptibility testing system. The enterotube ii procedure, result interpretation. Gas positive is a definite and complete separation of the white wax overlay from the surface of the. This item has been discontinued by the manufacturer and is no longer available. The bd vacutainer one use holder is a quality, lowcost single use holder that can help customers comply with osha regulations. Bd bionutrients technical manual a manual dedicated to products used in cell. Once inoculated, the panels provide a safe and easytohandle closed system. Today, bd is one of the largest microbiology companies. Bd vacutainer venous blood collection tube guide bd diagnostics preanalytical systems 1 becton drive franklin lakes, nj 07417 usa invert gently,do not shake the performance characteristics of these tubes have not been established for infectious disease testing in general. Identifying unknown bacteria using biochemical and.

Enteropluritest is a 12sector system containing special culture media that permits identification of the enterobacteriaceae and other gram negative, oxidase negative bacteria. Bd announces launch of bd vacutainer push button blood. Bbl enterotube enteropluri by bd global scientific. Pdf aims to improve the quality of life among persons. Microorganism is identified evaluating the color change of the different culture media after 1824 hours of incubation at 36 1 c and by a code number obtained from biochemical reaction interpretation. This item is made in italy and distributed by becton dickenson. I enteropluritestidentification system of enterobacteriaceae and other gram negative, oxidase negative bacteria. For the rapid identification of enterobacteriaceae. Aiming to benefits more than 5000 physicallychallenged and underprivileged people, each year pdf organize this event. Bd 1 becton drive franklin lakes, nj usa 07417 201. The becton dickinson bbl enterotube ii system for identification of members of the order parag saxena 259 words view diff exact match in snippet view article find. In june 1997, bd announced the acquisition of difco laboratories, inc. Product contains the same set of 25 tubes for identification of bacteria.

Bd continues to support researchers by introducing innovative tools to study multiple aspects of bcell biology. Enteropluritest identification system of enterobacteriaceae and other gram negative, oxidase negative bacteria. Catalog number 231746 enterotubes ii need 5 or less becton, dickinson, and company. To perform rapid differential identification of gramnegative bacteria enterobacteriaceae using the the enterotube ii. Bd 211832 vogesproskauer vp utilized confirmatory test only. Acid end products from glucose fermentation turn the ph indicator from red alkaline to yellow acid. Unless otherwise noted, bd, the bd logo and all other trademarks are property of becton, dickinson and company.

Enterotube ii is a selfcontained sterile plastic tube with 12 compartments containing distinct media that permit different biochemical tests to be performed. Principles and explanation of the procedure microbiological method. Find link is a tool written by edward betts becton dickinson is a redirect to bd company. The results of this oxidase test determine if students use an enterotube or an oxiferm tube in the next. Bd vacutainer edta lavender, tan, and pink top tubes bd vacutainer lithium heparin green top tube posted 03232018 audience. In 1955, bd acquired the baltimore biological laboratory bbl of baltimore, maryland, and used its expertise to continually advance the clinical market with prepared media and diagnostic tools. Apr 25, 2018 bd vacutainer edta lavender, tan, and pink top tubes bd vacutainer lithium heparin green top tube posted 03232018 audience. Quality of a specimen depends of preanalytical variables like specimen collection, physiologic and endogenous interference factors 1,2. Bd leads in health care safety including medication safety, health care worker safety and infection prevention as well as the technologies that enable medical research and. Summer challenge is a 45days long competition where 20 teams with 10 people each compete to bring positive change to our society. The enterotube ii is an example of a rapid, multi test system used in identification of unknown oxidase negative, gram negative, rod shaped bacteria of the family enterobacteriaceae. The system allows the simultaneous inoculation of all media present in the sectors and the execution of 15. Identifying unknown bacteria using biochemical and molecular. Manual of clinical microbiology 1985, 4th edition asm.

It also enables workflow efficiency by utilizing automated nephelometry. Manual and automated instrumentation for identification of. Former bd bbl enterotubes item 211832 now bd bbl enteropluri item 215336. Bd vacutainer venous blood collection tube guide bd diagnostics preanalytical systems 1 becton drive franklin lakes, nj 07417 usa invert gently, do not shake the performance characteristics of these tubes have not been established for infectious disease testing in general. Samples processed in these tubes are used for plasma.

Preanalytical variables account for most of laboratory errors and there are many factors that affect and contribute to the results from a patient. Bd diagnostics, a segment of bd becton, dickinson and company, announces the u. Bbl enterotube ii is a selfcontained, compartmented plastic tube containing twelve different media that allow the determination of 15 biochemical reactions glucose, gas production from glucose, lysine. This holder is compatible with bd vacutainer eclipse blood collection needles, bd vacutainer safetylok blood collection sets, and the bd vacutainer multiple sample luer adapters. Feb, 2018 becton, dickinson and company price becton, dickinson and company quote. Bd material safety data sheets msdss will also be referred to as safety data sheets sdss to align with global harmonization standards ghs and the newly approved may 28, 2010 american national standards institute ansi, standard z400. The bd bbl crystal identification system is a miniaturized identification system that requires only one step for inoculation. Bd phoenixspec nephelometer the bd phoenix nephelometer is a portable device that measures the turbidity of microbial suspensions used in specimen preparation. Bd micro, guide enterotube ii interpretation guide. Newly defined, key markers include the transcription factors blimp1. Recheck the biocode to be certain that the biochemical profile does not contain a positive result for both phenylalanine deaminase and dulcitol. Bd is recalling their vacutainer edta blood collection tubes with lavender, tan, pink and green rubber tube stoppers due to a chemical in the rubber tube stopper that interferes with the accuracy of the anodic. Bd is a global medical technology company that is advancing the world of health by improving medical discovery, diagnostics and the delivery of care. Bd offers broths and reagents for the bd phoenix automated identification and susceptibility testing system.

Bd diagnostics diagnostic systems becton dickinson. Phoenix ref microscan dried gram negative panel qc set. Description enteropluritest is a 12sector system containing special culture media that permits identification of the enterobacteriaceae and other gram negative, oxidase negative bacteria. Catalog number 211832 oxiferm tubes ii need 5 or less becton, dickinson, and company. Mck48152800 becton dic tube holder bd vacutainer standard size, clear, nonstackable, single use, 250 shelf pack for mm and 16 diameter tubes 3. Oct 15, 2014 bd sst ii advance tube becton, dickinson and company, franklin lakes, nj, usa requires a minimum clotting time of 30 minutes prior to centrifugation to obtain serum. Oxiferm ref bd phoenix gram negative ast nmicid qc set. Becton dickinson bd is a global medical technology company that is advancing the world of health by improving medical discovery, diagnostics and the delivery of care. An example of a commercially available manual bmd is sensititre trek diagnostic systems, cleveland, oh. The crystal mind software can also be used under manual mode without. Samples collected in these tubes are used for plasma determinations in chemistry for your business. Enteropluritest enterotube replacement medix, your on.

The bbl bd enterotube bd bbl enteropluri is a selfcontained, compartmented plastic tube which contains 12 different growth media and an. Bd leads in patient and healthcare worker safety and the technologies that enable medical research and clinical laboratories. Bd vacutainer pst lithium heparin tubes eliminate the need to wait for a clot to form, making it an ideal tube for stat procedures, as well as for patients receiving anticoagulant therapy. Also, eventually check that the organism is a gram negative rod. The readytouse product has been designed to help protect healthcare workers from accidental needlestick injuries nsis during the blood collection process and to prevent. Gas positive is a definite and complete separation of the white wax overlay from the surface of the glucose medium.

Bdhubcutterforhypodermicneedlesrussianlabel inaverage400600needles 32 305309 description needledimensions isocolourcode boxcontent itemnumber units 0. Bdhubcutter description fillcapacity boxcontent itemnumber units bdhubcutterforhypodermicneedles inaverage400600needles 32 305307 bdhubcutterforhypodermicneedlesrussianlabel inaverage400600needles 32 305309 description needledimensions isocolourcode boxcontent itemnumber units 0. The bd bbl enterotube ii incorporates 15 standard biochemical tests contained in a unique, readytouse, compartmented tube designed to permit the simultaneous inoculation of 12 test media. Bd enterotube becton, dickinson and company bd express becton, dickinson and company bd ez scrub becton, dickinson and company. Bd is a leading medical technology company that advances human health in every corner of the world by improving medical research, diagnostics and the delivery of care. Newly defined, key markers include the transcription factors blimp1 and xpb1s. Fda issued recall on bd vacutainer blood collection tubes by becton, dickinson and company bd due to chemical interference with certain tests. The enteropluri contains 24 prepared multimedia tubes. Fda strain seattle 1946 dsm 1103, ncib 12210 type strain.

Bd vacutainer sodium heparin tubes are spraycoated with sodium heparin. Enterotube ii the enterotube ii, first designed and marketed by roche diagnostics in 1969, was eventually sold to becton dickinson and is used for the identification of enterobacteriaceae and four commonly isolated oxidasenegative nonfermenters. Enterotube has its own enclosed inoculating wire that allows inoculation and completion of 15 standard biochemical. The system allows the simultaneous inoculation of all media present in the sectors and the. Trademark index the trademarked terms on this list appear in vwr publications and on this web site. The bd phoenix automated identification and susceptibility testing system provides rapid, accurate and reliable detection of known and emerging antimicrobial resistance. The becton dickinson bbl enterotube ii system for identification of members of the order parag saxena 259 words view diff exact match in snippet view article find links to article school of the university of pennsylvania. Pseudomonas aeruginosa schroeter migula atcc 27853. Enterotube has its own enclosed inoculating wire that allows inoculation and completion of 15 standard biochemical tests for the identification of enteric unknowns. Any biochemical test result obtained from the bbl enterotube ii which is cm273176. The bd bbl enterotube ii incorporates 15 standard biochemical tests contained in a. Escherichia coli migula castellani and chalmers atcc 25922 forprofit.

Bectondickinson, 384021, bd introsyten precision introducer. Manual of microbiological culture media becton dickinson. The first edition, published in 2003, replaced the difco manual, 11th ed. Specimen collection variables, such as, duration of fasting, time of specimen collection. Becton, dickinson and company price becton, dickinson and company quote. Bd phoenix automated identification and susceptibility. Escherichia coli migula castellani and chalmers atcc. We do not have any document for this combination of countrylanguage and catalog number. Bd, bd logo and all other trademarks are the property of becton, dickinson and company. This product is similar to the discontinued enterotube ii. To provide plasma advantage, becton dickinson offers the bd rst becton, dickinson and company, franklin lakes, nj, usa. Formerly known as the bd bbl bd enterotube ii, it has been renamed as the bd bbl enteropluri. The bd bbl enterotube has been replaced by the bd bbl enteropluri.

1191 920 695 685 316 1481 519 1486 833 1112 505 730 90 1619 1023 1536 157 1111 368 380 1585 180 669 183 899 321 541 148 1235 646 1078 502 139 822 123 132 936 179 1284 405 1006 195 384